The HT6800-200GTMUX-1 is a high-density 200G CFP2 Muxponder card for the HT6800 DCI DWDM Optical Transmission System. The client side provides 20×SFP+ ports for 20×10GE service access, while the line side accommodates one CFP2 coherent DCO module for 1×200GE output. Supports flexible wavelength tuning across the C-band and occupies 2 slots in the HT6800 chassis.
20 SFP+ ports on the client side supporting 20×10GE service access, enabling high-density aggregation for enterprise and carrier networks.
Line side supports 1×CFP2 coherent DCO module for 1×200GE or 1×100GE DWDM output, with flexible modulation format selection.
Supports 190.7–196.65 THz C-band with adjustable wavelengths at 50/75/100/150 GHz intervals for full DWDM grid compatibility.
Supports DDM digital diagnosis, OSNR monitoring, and real-time BER monitoring for proactive fault detection and performance management.
Supports ALS, LFP, local fault insertion, and transparent transmission of Local Fault and Remote Fault signals for comprehensive protection.
Full LLDP and RMON statistics support plus delay measurement and hardware/software loopback test for efficient commissioning.
| Performance Parameters | |
| Model | HT6800-200GTMUX-1 |
| Client-side Bandwidth | 20×10 Gbps (20×SFP+) |
| Line-side Bandwidth | 1×200 Gbps (CFP2 DCO) |
| Service Type | 10G and other service access |
| Chassis Slot Usage | 2 Slots (HT6800 series chassis) |
| Power Dissipation | ≤80W |
| Optical Parameters | |
| Center Wavelength | 190.7 ~ 196.65 THz |
| Wavelength Grid | 50 GHz / 75 GHz / 100 GHz / 150 GHz (adjustable) |
| Output Power | Adjustable range depending on DCO module type |
| Supported Functions | |
| DDM Monitoring | Digital diagnosis, OSNR monitoring, real-time BER monitoring |
| RMON | Packet/byte count, port utilization, CRC errors, error packets |
| LLDP | Supported |
| Delay Measurement | Supported |
| ALS / LFP | Supported |
| Fault Insertion | Local fault insertion; transparent LF/RF transmission |
| Loopback Test | Port hardware and software loop test |
OSNR tolerance values for supported modulation formats on the HT6800-200GTMUX-1 line card.
| Modulation Format | Line Rate | OSNR Tolerance |
|---|---|---|
| DP-QPSK-OFEC | 100G | 12.5 dB |
| 8QAM-OFEC | 200G | 20 dB |
| DP-QPSK-OFEC | 200G | 14 dB |
| Physical Dimensions | |
| Width | 216 mm |
| Depth | 254 mm |
| Height | 42 mm |
| Environmental Specifications | |
| Working Temperature | -5°C ~ 45°C |
| Storage Temperature | -40°C ~ 80°C |
| Relative Humidity | 5% ~ 95% (no condensation) |
| Power | |
| Max Power Dissipation | ≤80W |
| Interface Specifications | |
| Client Side | 20×SFP+ (10 Gbps per port) |
| Line Side | 1×CFP2 DCO 200Gbps DWDM module |
| Line Side Alt Mode | Also supports 1×100GE CFP2 DCO |
| Compatibility | |
| Compatible Chassis | HT6800 series (supports mixed insertion of electrical/optical layer cards) |
| Compatible Modules | HT6800-OA, HT6800-OLA, HT6800-OP1/OP2, HT6800-WSS09, HT6800-OTDR, HT6800-OCM, HT6800-TFFxxxx |
Our team is ready to help with technical consultation, OEM/ODM support, and project deployment.